The cookie settings on this website are adjusted to allow all cookies so that you have the very best experience. If you continue without changing your cookie settings, we'll assume that you are happy to receive all cookies on our website. However, if you would like to, you can change your settings at any time using the Change cookie settings link in the Special menu. 
    
 
Home :: Radios and Equipment :: Passive Oscilloscope Probe Type M-12X1

Passive Oscilloscope Probe Type M-12X1

Passive Oscilloscope Probe Type M-12X1
SKU 1585
Weight 0.30 Kg
Equipment Grade Grade 1
£10.00 (Approximately US$ 12.80)
Qty
Passive Oscilloscope Probe Type M-12X1
The Oscilloscope Probe Type M-12X1 is a miniature X1 passive probe intended for use with a wide range of oscilloscopes. These probes were manufactured to the highest specification in England for use in the military workshops and have a NATO Stock Number Z4-6625-99-726-2877. The probes modular construction facilitates simple field replacement of the major parts (see dismantling section below). The probe is supplied Brand New with a complete range of accessories.

Specifications:
Lead Length: 1.2 Meter.
Nominal Input Capacitance: 45 P.F.
Bandwidth: 30 MHz.
Approximate Rise Time: 11 nS.
Oscilloscope Input Resistance: 1 M Ohm.
Maximum Input Voltage: 600 Volts DC & peak AC.
Temperature Range: -25 to +70C.
Supplied Accessories:
Sprung Hook.
BNC Adapter.
Insulating Tip.
Spare Measuring Tip.
I.C. Adapter.
Ground Lead ? 15 Cm

Dismantling Instructions

Dismantling the probe is a service operation only, DO NOT attempt to dismantle the probe whilst it is still connected to a voltage source.

1) The earth lead may be removed by gripping the earth ring (5) and sliding it towards the measuring tip.
2) The probe head (4) may be removed by holding the cable connector (3) and unscrewing the head in a counter clockwise direction when viewed from the measuring tip.
3) The measuring tip (6) may be removed by unscrewing it in a counter-clockwise direction.
4) The terminating box (1) may be removed together with its shroud (2) by holding the cable connector (3) and unscrewing the box in a counter-clockwise direction when viewed from the BNC connector.
5) Assembly of the probe is carried out in the reverse order making sure that all connections are tight.